3.8.3 Reset to factory default
“Reset to factory default” allows user to reset controller to factory default setting.
Figure 3.8.3.1
Reset to default value, the password is: 1234, and IP address to default DHCP.
Default IP address: 192.168.10.50 (DHCP)
Default subnet mask: 255.255.255.0
Default gateway: 192.168.10.254
3.8.4 Import and export
“Import and export” allows user to save system configuration values: export, and apply all configuration:
import. For the volume configuration setting, the values are available in export and not available in import
which can avoid confliction/date-deleting between two controllers. That says if one controller already
exists valuable data in the disks and user may forget to overwrite it. Use import could return to original
configuration. If the volume setting was also imported, user’s current data will be overwritten.
Figure 3.8.4.1
1. Import: Import all system configurations excluding volume configuration.
2. Export: Export all configurations to a file.
Tips
Please contact with tech@sansdigital.com for latest firmware.
Caution
“Import” will import all system configurations excluding volume configuration; the current
confi
g
urations will be re
p
laced.