5. Done. A RG has been created.
Figure 3.6.7.2
(Figure 3.6.7.2: Creating a RAID 5 with 3 physical disks, named “RG-R5”. The total size is 931GB. Because
there is no related VD, free size still remains 931GB.)
Step 2: Create VD (Virtual disk).
To create a data user volume, please follow the procedures.
Figure 3.6.7.3
5. Select “/ Volume configuration / Virtual disk”.
6. Click “
”.
7. Input a VD name, choose a RG Name and enter a size of VD; decide the stripe high, block
size, read/write mode and set priority, finally click “
“.
8. Done. A VD has been created.
9. Do one more time to create another VD.
Figure 3.6.7.4
(Figure 3.6.7.4: Create VDs named “VD-R5-1” and “VD-R5-2”. Regarding to “RG-R5”, the size of “VD-
R5-1” is 50GB, the size of “VD-R5-2” is 64GB. “VD-R5-1” is initialing about 86%. There is no LUN
attached.)
Step 3: Attach LUN to VD.
There are 2 methods to attach LUN to VD.
Vue de la page 42